NOTE: The ICS for ACQUITY UPC 2 and M-Class support are not on the SCN 943 DVD. NOTE: Instructions for installing the ACQUITY Components can be found in the Installing ACQUITY Driver Components section, this will include configuration of the Isocratic Solvent Manager. NOTE: OpenLynx is included on all installations of SCN 943 with the Xevo TQ-XS. NOTE: If MassLynx V4.2 SCN 943 is reinstalled, all Acquity components should be reinstalled. NOTE: Modifying or repairing an installation via the Setup.exe is not supported. of 39 Document No: 48925_1ħ Software Deployment: MassLynx 4.2 SCN 943 is a complete installation of MassLynx 4.2. Included Drivers: The MassLynx 4.2 SCN 943 installation includes the following drivers: MS SCN Version Xevo TQ-XS SCN 943 LC / Inlets ICS Version Waters Driver Pack 4 SR1 1.6 Driver Pack 4 SR1 GC - Agilent of 39 Document No: 48925_1ĥ Supported Components: The MassLynx 4.2 SCN 943 installation supports the following drivers, for configuration recommendations, please contact your local Waters specialist: Components ACQUITY UPLC, H-Class, I-Class and M-Class Systems ACQUITY Binary Solvent Manager (BSM) ACQUITY Sample Manager (SM) ACQUITY FLR Detector ACQUITY Sample Organizer and CPSO ACQUITY Column Manager (CM) ACQUITY PDA Detector ACQUITY TUV Detector ACQUITY ELS Detector ACQUITY FLR Detector ACQUITY Open Architecture System (Waters 2777 Autosampler) ACQUITY Isocratic Solvent Manager ACQUITY Sample Manager FTN ACQUITY Quaternary Solvent Manager ACQUITY Convergence Manager ACQUITY UPC 2 BSM ACQUITY Auxiliary Solvent Manager (ASM) ACQUITY Binary Solvent Manager ( BSM) ACQUITY Binary Sample Manager-FL ACQUITY Sample Organizer (SO) ACQUITY Trap Valve Manager (TVM) Waters Pump Control (WPC) Waters 2996 PDA Waters 2695 (controlled via GPIB) ealliance - controlled via GPIB of 39 Document No: 48925_1Ħ Operating Systems: Microsoft Windows 7 Professional 64 bit, Service Pack 1 Security: Basic and Full MassLynx security configurations are supported. Using RADAR, which enables rapid switching between MS full scan and MS/MS acquisition modes, analysts can understand sample complexity and improve method development. Xtended Dynamic Range (XDR) technology provides accessible sensitivity and method transfer. Robust sensitivity is enabled by proven ZSpray and StepWave which facilitate the detection of analytes at low concentrations in complex matrices and enable low volume injections with accurate, precise, and consistent results. The Xevo TQ-XS is a sensitive tandem quadrupole mass spectrometer featuring reliable performance with a wide dynamic range and high rates of data acquisition. This software change note includes new enhancements, fault fixes and concessions as described in the Enhancement, Fault Fixes and Concessions sections of this document. MassLynx Software Change Note #943 provides support for the Waters Xevo TQ-XS Mass spectrometer. 7 PREPARATION 7 INSTALLATION PROCEDURE 8 Installation of Stand Alone Applications 8 Installation of Quanpedia databases 9 Adobe Print Driver Setup 9 UN-INSTALLATION: 10 MS FEATURES: 11 FAULT FIXES: 11 CONCESSIONS: 11 INLETS FEATURES: 18 FAULT FIXES: 18 CONCESSIONS: 18 APPLICATIONS FEATURES: 19 FAULT FIXES: 19 CONCESSIONS: 19 SUPPORTED COMPUTERS, OPERATING SYSTEMS, HOT FIXES AND ANTI-VIRUS SOFTWARE: SUPPORTED COMPUTERS AND OPERATING SYSTEMS 21 HOT FIXES 21 ANTIVIRUS 23 WINDOWS UPDATES 23 of 39 Document No: 48925_1ģ INSTALLING ACQUITY DRIVER COMPONENTS AGILENT 7890 GC SUPPORT of 39 Document No: 48925_1Ĥ MassLynx Software Change Note #943 Introduction: MassLynx Software Change Note #943 is the first release of MassLynx version V4.2. 1 MassLynx TM 4.2 SCN 943 Release Notes of 39 Document No: 48925_1 Waters is a registered trademark, Waters the Science of What s Possible and MassLynx are trademark of Waters Corporation All other trademarks are the sole property of their respective owners Copyright 2016 Waters CorporationĢ INTRODUCTION.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |